Error codes for Triangle Tube Boiler

Triangle tube Boiler is a gas boiler that uses a closed loop circulatory system to distribute and exhaust heat to the room where the boiler is located. It has a pipe that surrounds the boiler and it has different ports that allow air to circulate through it.

Triangle tube Boiler is one of the most common types of boilers and they are used in homes, businesses and institutions. These boilers are also known for being efficient because they have low operating costs, low noise levels and no toxic emissions.

It has different features that you can use to improve its efficiency, such as a hot water system that distributes hot water from the top of the boiler to your bathrooms, showers or kitchen. The water temperature can be regulated by means of a thermostat or an electronic temperature controller depending on your needs.

Tech Support 24/7
Ask a Tech Specialist Online

Connect with the Expert via email, text or phone. Include photos, documents, and more. Get step-by-step instructions from verified Tech Support Specialists.

In addition, there are different features that you can use to increase efficiency such as a heat recovery system that captures heat from the exhaust pipe and recirculates it through the hot water pipes to your bathroom, showers or kitchen.

Sometimes, you might find some errors in the product. Let’s dive into some errors you might find while using it and let’s find out about what you should do.

10 – 14

If the display shows 10, 11,12, 13,14, it means there is a CH Supply Sensor fault S1. You can check the wiring and a proper flow direction. Replace S1, if necessary. Use E10 open sensor and E11 short sensor.

20 – 24

CH Supply Sensor fault S2 could make you encounter error codes 20, 21, 22, 23, 24. Similar to the ways above, please check the wiring and a proper flow direction. You can replace S2 and use E20 open sensor and E21 short sensor.

0

Meanwhile error code 0 means there is a sensor fault after checking. The only possible solution is to replace the S1 and/or S2.

Tech Support 24/7
Ask a Tech Specialist Online

Connect with the Expert via email, text or phone. Include photos, documents, and more. Get step-by-step instructions from verified Tech Support Specialists.

Error codes for Triangle Tube Boiler

1.28

If the temperature is too high, you might encounter error code 1.28. Make sure there is an enough flow in the installation and make sure the pump is running well.

 4

Error code 4 means there is no flame signal. It could be because the manual gas shut off valved is closed, no ignition gap, or even the gas supply pressure is too low. Make sure the gas valve or ignition unit is powered well.

5

Error code 5 gives you a signal that there is a poor flame. Check the alteration of the gas valve because it might be because of condensate deplete blocking.

6

You can supplant start cable and start plug cap if you find error code 6. Also, supplant start unit at gas valve and supplant kettle controller.

8

Another example is error code 8, which means an incorrect fan speed. Check wiring for destitute wire contact or you can replace the fan.

Those are some examples of error codes you might find when using Triangle Tube Boiler. If a problem persists, you can contact customer service to fix your problem.

(Visited 56 times, 1 visits today)