York AC is a popular brand of air conditioners and heaters. This company is also known for being a reliable company that offers quality products. It was established in 1933, and it was originally known as York Air Conditioning Company. The company became famous after the founding of York in 1953.

This company is famous for its York line of products, including the York ADM, ADM 3100, ADM 5000 and the ADM 5500. These products are available in different countries such as the United States, Canada and many other countries around the world. The air conditioners and heaters offered by this brand are popular because they are reliable, and they offer quality features.

If you encounter an error while using your York product, then you might encounter an error code on your device’s screen.

Tech Support 24/7
Ask a Tech Specialist Online

Connect with the Expert via email, text or phone. Include photos, documents, and more. Get step-by-step instructions from verified Tech Support Specialists.

E1

E1 error code means there is a malfunction in indoor and also outdoor unit communication. This error may happen due to a loose wire, connection problem or damaged insulation. To fix this error, you can try cleaning the fan motor’s cooling fins. You can also check the fuse and replace it if it is blown.

E3

E3 error code means there is a malfunction in the indoor fan speed. This error is probably because of an electrical fault. To fix this error, you can replace the fuse. If the fan is still working, then you need to check the wiring or check the electrical installation.

EE

EE error code means there is a malfunction in the water level alarm. This error may happen if the water pump is not working properly. To fix this, you can see the water level and replace the pump.

F0

F0 means that there is an overload protection. The error may occur due to an overload in the fan motor or a damaged or broken wiring. To fix this error, you can remove the filter from the outdoor unit and check if there is any obstruction in the fan motor’s cooling fins.

P1

P1 means that there is a high and low voltage protection. This error may occur due to a damaged electrical circuit board in the compressor’s indoor unit or any wiring problem in the outdoor unit. You can remove the filters from both indoor and outdoor units and check if they are blocked or clogged.

Tech Support 24/7
Ask a Tech Specialist Online

Connect with the Expert via email, text or phone. Include photos, documents, and more. Get step-by-step instructions from verified Tech Support Specialists.

E8

E8 means that there is a malfunction in the dual indoor unit communication. This error may occur due to broken or damaged wiring or a loose wire connection. To fix this error, you can remove the filters from both indoor units and check if there is any obstruction in the fan motor’s cooling fins.

F1

F1 means that there is an error on the outdoor temperature sensor. To fix this error, you can try cleaning and lubricating the outdoor unit’s shaft. You can also try replacing the outdoor unit’s compressor motor if it is faulty.

(Visited 67 times, 1 visits today)

Comments

mood_bad
  • No comments yet.
  • Add a comment